What was found
INSPECTION FOUND MIDDLE SECTION OF SEAT MOUNTED EMERGENCY PATH LIGHTING INOPERATIVE. MAINTENANCE FOUND MOST OUTBOARD FUSE OF MIDDLE POWER SUPPLY PACK BLOWN. THE FUSE WAS REMOVED AND REPLACED AND OPERATION OF THE LIGHTING WAS RESTORED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND MIDDLE SECTION OF SEAT MOUNTED EMERGENCY PATH LIGHTING INOPERATIVE. MAINTENANCE FOUND MOST OUTBOARD FUSE OF MIDDLE POWER SUPPLY PACK BLOWN. THE FUSE WAS REMOVED AND REPLACED AND OPERATION OF THE LIGHTING WAS RESTORED.