What was found
INSPECTION FOUND AFT CARGO COMPARTMENT LONGERON 23L STRAP BETWEEN STA 937 AND 967 CORRODED. THE FASTENERS AND STRAP WERE REMOVED IAW SRM 51-30-2. THE SURFACE CORROSION WAS REMOVED IAW SRM 51-10-3. A NEW STRAP WAS INSTALLED IAW SRM 51-01-0, 51-10-3, AND 51-30-2.