What was found
INSPECTION FOUND A .375 INCH AND .125 INCH CRACK AT LT WING NR 2 SLAT LOWER CHORD BELOW TELESCOPING ANT-ICE TUBE. THREE ACCESS PANELS WERE REMOVED PER SRM 51-30-2 AND THE CRACKS WERE STOP DRILLED IAW SRM 51-10-1, PAGE 6B. AN ANGLE REPAIR DOUBLER WAS INSTALLED IAW SRM 51-10-2 AND 51-40-1. THE THREE ACCESS PANELS WERE REINSTALLED IAW SRM 51-30-2.