What was found
INSPECTION FOUND CABIN FLOORBEAM CORRODED AT STA 294, RBL 35. THE CORROSION WAS REMOVED AND A NEW SECTION OF FLOORBEAM WAS SPLICED IN IAW SRM 53-10-51, FIGURE 205.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND CABIN FLOORBEAM CORRODED AT STA 294, RBL 35. THE CORROSION WAS REMOVED AND A NEW SECTION OF FLOORBEAM WAS SPLICED IN IAW SRM 53-10-51, FIGURE 205.