What was found
INSPECTION FOUND CABIN FLOORBEAM CORRODED AT STA 346 FROM RBL 15 TO LEFT SIDEWALL. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED. A NEW SECTION OF FLOORBEAM AND SPLICE WERE INSTALLED IAW SRM 53-10-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND CABIN FLOORBEAM CORRODED AT STA 346 FROM RBL 15 TO LEFT SIDEWALL. THE CORRODED SECTION OF FLOORBEAM WAS REMOVED. A NEW SECTION OF FLOORBEAM AND SPLICE WERE INSTALLED IAW SRM 53-10-51.