What was found
INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT IN FORWARD CARGO AREA AT STA 899, RBL 45-65. THE FLOOR SUPPORT WAS REMOVED AND A NEW ONE WAS INSTALLED IAW SRM 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT IN FORWARD CARGO AREA AT STA 899, RBL 45-65. THE FLOOR SUPPORT WAS REMOVED AND A NEW ONE WAS INSTALLED IAW SRM 51-31-01.