What was found
INSPECTION FOUND FORWARD CARGO BAY STRINGER 44R END CAP CORRODED AT STA 889. THE END CAP WAS REPAIRED IAW SRM 53-30-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FORWARD CARGO BAY STRINGER 44R END CAP CORRODED AT STA 889. THE END CAP WAS REPAIRED IAW SRM 53-30-00.