What was found
INSPECTION FOUND A 2 INCH CRACK IN SUBFLOOR CUSP WEB AT STA 195, RBL 9. THE SUBFLOOR CUSP WEB WAS REPAIRED IAW SRM 53-01, FIGURE 4, SHEET 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 2 INCH CRACK IN SUBFLOOR CUSP WEB AT STA 195, RBL 9. THE SUBFLOOR CUSP WEB WAS REPAIRED IAW SRM 53-01, FIGURE 4, SHEET 3.