What was found
INSPECTION FOUND A .5 INCH CRACK IN AFT CARGO DOOR AFT VERTICAL RIB LOWER END FITTING. THE FITTING WAS REMOVED AND REPLACED IAW SRM 51-30-1, 51-30-2, AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .5 INCH CRACK IN AFT CARGO DOOR AFT VERTICAL RIB LOWER END FITTING. THE FITTING WAS REMOVED AND REPLACED IAW SRM 51-30-1, 51-30-2, AND 51-30-5.