What was found
INSPECTION FOUND THE LT OVERWING EMERGENCY LIGHTS IN MID AND AFT POSITIONS INOPERATIVE. MAINTENANCE FOUND A CHAFED WIRE BEHIND WHEEL WELL FAIRING PANEL AREA. THE WIRE WAS REPAIRED AND OPERATION CHECKED GOOD IAW MM 33-51-01, PAGE 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND THE LT OVERWING EMERGENCY LIGHTS IN MID AND AFT POSITIONS INOPERATIVE. MAINTENANCE FOUND A CHAFED WIRE BEHIND WHEEL WELL FAIRING PANEL AREA. THE WIRE WAS REPAIRED AND OPERATION CHECKED GOOD IAW MM 33-51-01, PAGE 6.