What was found
INSPECTION FOUND A .5 INCH CRACK IN O/B FLOOR SUPPORT AT RT FUSELAGE WALL FS 760. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-30-2, 51-10-2, AND MM 51-20-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .5 INCH CRACK IN O/B FLOOR SUPPORT AT RT FUSELAGE WALL FS 760. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-30-2, 51-10-2, AND MM 51-20-0.