What was found
INSPECTION FOUND FLOORBOARD SUPPORT CORRODED AT STA 420, RBL 12-25. THE SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-30-2, 51-10-2, AND MM 51-20-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBOARD SUPPORT CORRODED AT STA 420, RBL 12-25. THE SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-30-2, 51-10-2, AND MM 51-20-0.