What was found
AT SHUT DOWN OF AIRCRAFT WHILE STARTING APU, AGB HYDRAULIC MOTOR PUMP STARTED LEAKING AND SPRAYING HYDRAULIC OIL. AFTER SHUTTING DOWN OF APU AND CLOSER INSPECTION OF AGB PUMP, FOUND CASE HALF MOUNTING EARS CRACKED IN HALF WHICH SEPARATED BACK HALF OF PUMP FROM FORWARD DRIVE SECTION. CAUSE UNKNOWN. (X)