What was found
EMERGENCY LIGHTS ON FLOOR BETWEEN ROWS 7 THROUGH 10 ARE INOP. FOUND EMERGENCY BATTERY NR 4 DISCONNECTED. RECONNECTED BATTERY IAW EMB 135 AMM 33-50-04. OPS CHECK GOOD. REPLACED LIGHT STRIP DUE TO BROKEN WIRE IAW EMB 135 AMM 33-20-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY LIGHTS ON FLOOR BETWEEN ROWS 7 THROUGH 10 ARE INOP. FOUND EMERGENCY BATTERY NR 4 DISCONNECTED. RECONNECTED BATTERY IAW EMB 135 AMM 33-50-04. OPS CHECK GOOD. REPLACED LIGHT STRIP DUE TO BROKEN WIRE IAW EMB 135 AMM 33-20-00.