As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING FLIGHT AT CRUISE, NOTICED A BURNING SMELL IN COCKPIT. NO MESSAGES OR INDICATIONS OF ANYTHING WRONG. SMELL DISSIPATED AND RETURNED THROUGHOUT FLIGHT. TURNING WINDSHIELD HEAT OFF IN DESCENT SEEMED TO MAKE THE SMELL STOP. MAINTENANCE INSPECTED AND FOUND TERMINAL MELTED ON RT WINDSHIELD. REMOVED AND REPLACED RT WINDSHIELD IAW CHQ JOBCARD E56-10-01-000-001-2. NO OTHER DEFECTS NOTED. AIRCRAFT OK FOR SERVICE.