As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
THE FLIGHT CREW REPORTED A BLEED 1 LEAK MESSAGE ON EICAS UPON ENTERING ICING CONDITIONS DURING CLIMB. THE CREW DIVERTED TO CLT AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE BLEED SYSTEM AND FOUND A LEAK AT JOINT 15 UNDER THE CARGO COMPARTMENT FLOOR. THE O-RINGS AND COVER BOOT WERE REPLACED IAW EMB145 MM 36-11-09. OPS AND LEAK CHECKS GOOD.