What was found
DURING INSPECTION, THE RIGHT EMERGENCY EXIT LIGHT WAS FOUND TO BE DIM WHEN ILLUMINATED. MAINTENANCE REPLACED THE NR 5 EMERGENCY LIGHT DC/AC INVERTER IAW EMB 140 AMM 33-50-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, THE RIGHT EMERGENCY EXIT LIGHT WAS FOUND TO BE DIM WHEN ILLUMINATED. MAINTENANCE REPLACED THE NR 5 EMERGENCY LIGHT DC/AC INVERTER IAW EMB 140 AMM 33-50-11.