What was found
ON ROTATION, CREW REPORTED A LOUD BANG & COULD SMELL ODOR OF RUBBER. ACFT CONTINUED TO CLIMBOUT WITH NO ISSUES & ALL INDICATIONS NORMAL. FLT CONTINUED. PRIOR TO LANDING, ACFT PERFORMED A FLY-BY OF TOWER & NO DEFECTS WERE REPORTED. ACFT LANDED WITHOUT INCIDENT. DURING POST FLT INSPECTION, LT INBOARD TIRE TREAD FOUND TO HAVE SEPARATED & DAMAGED LT INBOARD FLAP & DAMAGED NR 1 ENG FAN BLADES. MX INSPECTED & FOUND NO DAMAGE TO CORE ENGINE, & NO DAMAGE TO MLG. SEVERAL FAN BLADES, STATOR VANES, & FAN CASE REPLACED, ALONG WITH THE LT INBOARD FLAP & BOTH LT MLG WHEELS.