What was found
DURING INSPECTION, A DENT WAS FOUND ON THE CENTER FUSELAGE 1 SKIN BETWEEN FRAMES 19 AND 20 THAT WAS BEYOND LIMITS. THE DENT MEASURED 3 INCHES WIDE, BY 2.8 INCHES LONG AND 0.064 INCHES DEEP. A HIGH FREQUENCY EDDY CURRENT INSPECTION WAS PERFORMED WITH NO CRACKS DETECTED. THE DENT WAS THEN FILLED IN ACCORDANCE WITH SRM 51-74-00.