What was found
DURING INSPECTION, CORROSION WAS FOUND ON THE CENTER FUSELAGE I FLOOR STRUCTURE LEFT SILL NUMBER 1. THE CENTER FUSELAGE I FLOOR STRUCTURE LEFT SILL NUMBER 1 WAS REPLACED AND INSTALLED WITH A SOLID RIVET.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.