What was found
DURING INSPECTION, CORROSION WAS FOUND ON THE RAMP ANGLE FRAME 20 AT THE CENTER OMEGA BEAM. THE ANGLE AT FRAME 20 WAS REPLACED IN ACCORDANCE WITH SRM 51-40-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, CORROSION WAS FOUND ON THE RAMP ANGLE FRAME 20 AT THE CENTER OMEGA BEAM. THE ANGLE AT FRAME 20 WAS REPLACED IN ACCORDANCE WITH SRM 51-40-03.