What was found
CREW REPORTED THAT DURING FLIGHT THE HYD SYS 1 QTY DROPPED TO THE TOP OF THE AMBER RANGE. THE ACFT DIVERTED & LANDED WITHOUT INCIDENT. FOUND THE HYD SYS 1ENG DRIVEN PUMP LEAKING. THE PUMP WAS REPLACED & NO FURTHER DEFECTS WERE NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CREW REPORTED THAT DURING FLIGHT THE HYD SYS 1 QTY DROPPED TO THE TOP OF THE AMBER RANGE. THE ACFT DIVERTED & LANDED WITHOUT INCIDENT. FOUND THE HYD SYS 1ENG DRIVEN PUMP LEAKING. THE PUMP WAS REPLACED & NO FURTHER DEFECTS WERE NOTED.