Service difficulty report · Sensor · Emb EMB135KL

Difficulty date
July 12, 2014
Submitted
July 16, 2014
Operation
Air carrier
Aircraft
N297SK
Make and model
Emb EMB135KL
Aircraft serial
145522
Aircraft time
31,185 hours, 28,146 cycles
Engine
Rroyce AE3007A13
Engine time
27,245 hours, 27,699 cycles
Part
Sensor
Part number
0132ADT
Condition
Inoperative
Location
Bleed Air Sys
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

THE CREW REPORTED THAT THEY RECEIVED A BLD 2 OVERTEMP MSG IN FLIGHT WHEN ENTERING ICING CONDITIONS. AFTER FOLLOWING THE GRH BY CLOSING THE BLD 2 SYS & OPENING THE CROSSBLEED VLV, THE CREW REPORTED THAT A BLEED 1 LOW TEMPERATURE MSG APPEARED. THE CREW DIVERTED THE ACFT AND LANDING WITHOUT FURTHER INCIDENT. MX REPLACED THE NUMBER 2 PRECOOLER INLET TEMPERATURE SENSOR. OPERATIONAL CHECKS OF THE BLEED 1 * BLEED 2 SYSTEMS WERE GOOD WITH NO FURTHER DEFECTS NOTED.