What was found
DURING INSPECTION CORROSION WAS FOUND ON THE CTR OMEGA BEAM AT FRAME 20 UNDER THE RAMP ANGLE. THE CTR OMEGA BEAM WAS REPAIRED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION CORROSION WAS FOUND ON THE CTR OMEGA BEAM AT FRAME 20 UNDER THE RAMP ANGLE. THE CTR OMEGA BEAM WAS REPAIRED IAW SRM 51-40-02.