As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING COMPLIANCE OF RECURRING AD 87-02-06 EFFECTIVE 2-6-87, WHILE PERFORMING VISUAL INSPECTION AS REQUIRED BY PAR A (1) OF THE AD, A SUSPECTED CRACK WAS NOTED IN THE UPPER FORWARD RADIUS OF THE MOUNT. THE CRACK WAS CONFIRMED BY MAGNETIC PARTICLE INSPECTION AS REQUIRED BY PAR A (2)(B)(2) OF THE AD AND FOUND TO BE .3750 INCH LONG. THE UNIT WAS REPLACED WITH A NEW UNIT P/N 2651034-3 AS REQUIRED BY PAR A (2)(B)(1) OF THE AD. (X)