What was found
OSC - DURING D-CHECK, FOUND APPROX 2.75 INCH LONG CRACK, LEFT MLG SUPPORT ATTACHED FITTING. REF DOUG SB 57-94, FIG 1, VIEW FF LOCATION E. REMOVED AND REPLACED LEFT MLG FITTING IAW AD 89-10-04 AND SB 57-94 AND FAA LETTER DATED 11-4-94. (W)