What was found
HUF/IAH - FLT 72669 - ON EXTENSION, NOSE GEAR DID NOT GO GREEN UNTIL THIRD ATTEMPT. INSPECTED NOSE GEAR, FOUND NO DEFECTS. LUBED ALL GREASE FITTINGS IN NOSE. CLEANED AND RE-SECURED CANNON PLUGS ON BOTH SWITCHES. JACKED NOSE GEAR IAW 727 MM 7-11-0. PERFORMED NOSE GEAR RETRACTION TEST IAW 32-33-0. CYCLED 15 TIMES. POSITON AND WARNING SYSTEMS. OPS CHECK GOOD IAW 32-61-0. (X)