What was found
DURING 'C-1' CHECK INSPECTION FOUND, CARD NR 6000-0551 AREA, AFT FUSELAGE/VERTICAL STABILIZER. VERTICAL STABILIZER TO FUSELAGE ATTACH ANGLE RIGHT SIDE HAS STRESS CRACKS AND CORROSION. LEVEL 2 TASK NR 74799. CLEANED CORROSION AND FOUND TO BE OUT OF LIMITS. NO STRESS CRACKS FOUND. REPAIRED AREAS IN ATTACH ANGLE IAW DC-8 SRM 53-2-5, FIGURE 16A 51-1-20D. TREATED AND PAINTED IAW DC-8 SRM 51-1-8. (X)