What was found
DOSC - FLT 72016 - DURING 'C-1' CHECK INSPECTION FOUND, TASK NR 59644 PANEL 262F DELAMINATION. FABRICATED NEW PANEL IAW AIA SKETCH AIA/E/2188 AND INSTALLED. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DOSC - FLT 72016 - DURING 'C-1' CHECK INSPECTION FOUND, TASK NR 59644 PANEL 262F DELAMINATION. FABRICATED NEW PANEL IAW AIA SKETCH AIA/E/2188 AND INSTALLED. (X)