What was found
DURING C-2 CHECK, INSPECTION FOUND BATHTUB FITTING AT FS 310 STRINGER 31L CORRODED. REMOVED AND REPLACED FITTING PER SRM 53-2-0, 51-1-21, 51-1-20D AND 51-3-0. TASK NR 81008, CORROSION CARD NR 5570-0551.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-2 CHECK, INSPECTION FOUND BATHTUB FITTING AT FS 310 STRINGER 31L CORRODED. REMOVED AND REPLACED FITTING PER SRM 53-2-0, 51-1-21, 51-1-20D AND 51-3-0. TASK NR 81008, CORROSION CARD NR 5570-0551.