What was found
DURING C-1 CHECK INSPECTION, FOUND RUDDER 4TH STATIC WICK FROM TOP CORRODED RIGHT SIDE. REPAIRED STATIC WICKS AT ZR293 AND ZR284 IAW AIA DRAWING AIA/E/2434 REV ORIG AND DC-8 SRM 51-1-21, AND 51-1-21A, EA 96-348 REPORT NR 96 AIA 197 DATED 12-12-96. CORROSION CARD NR 6000-0551. NON-ROUTINE TASK CARD NR 89041, LEVEL 2.