What was found
DURING CPCP CHECK INSPECTION, FOUND LEVEL 2 CORROSION, FILLET PANEL APPROXIMATELY STA 1460 BETWEEN MAIN LANDING GEAR DOORS, JUST AFT OF APU SHROUD FUEL DUMP HAS CORROSION. REMOVED AND REPLACED PANEL IAW B747 SRM 51-10-1, CLEANED AND TREATED CORROSION IAW B747 SRM 51-10-6. REPLACED FASTENERS IAW B747 SRM 51-30-2. CORROSION TASK CARD NR C53-100-01 PART 4 OF 10. NON-ROUTINE TASK CARD NR 94135.