What was found
DURING C-1 CHECK INSPECTION, FOUND LEVEL 2 CORROSION A PIT DOOR LOWER AFT CORNER OF DOOR FRAME. CUT-OUT SECTION OF DOOR JAMB, FABRICATED REPLACEMENT DOOR JAMB. INSTALLED DOOR JAMB AND REPAIR ANGLES IAW AIA/E/2489 AND EA 97-013. C-1 CHECK INSPECTION WORK CARD NUMBER 3007. NON-ROUTINE TASK CARD NUMBER 92899.