What was found
DURING CPCP CHECK INSPECTION, FOUND INTERCOSTAL CRACKED STA 980 TO 1000 LONGERON 30 LT. REMOVED AND REPLACED INTERCOSTAL IAW DC8 SRM 51-1-0 AND 51-1-20D. CORROSION TASK CARD NUMBER 5590-0551. NON-ROUTINE TASK CARD NUMBER 93443.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CPCP CHECK INSPECTION, FOUND INTERCOSTAL CRACKED STA 980 TO 1000 LONGERON 30 LT. REMOVED AND REPLACED INTERCOSTAL IAW DC8 SRM 51-1-0 AND 51-1-20D. CORROSION TASK CARD NUMBER 5590-0551. NON-ROUTINE TASK CARD NUMBER 93443.