What was found
DURING CPCP CHECK INSPECTION, FOUND NR 4 PYLON DOOR 412 CUTOUT CRACKED INNER AND OUTER DOUBLER STA YOP208 UPPER SPAR AREA, NR 4 PYLON UPPER OUTBOARD SPAR CAP CRACKED STA YOP206, NR 4 PYLON UPPER OUTBOARD SPAR CAP CRACKED STA YOP224. INSTALLED REPAIR DOUBLER NR 4 PYLON UPPER OUTBOARD SPAR CAP IAW SRM 54-2-1 FIGURE 5 AND EER D8-05258 DATED 2-20-97 EA 97-017 B. CORROSION TASK CARD NUMBER 84-1-0551. NON-ROUTINE TASK CARD NUMBERS 93405, 93404, 93403.