As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CPCP CHECK INSPECTION, FOUND LEVEL 2 CORROSION FS 702 LBL 25 AT SEAT TRACK BOLTS ON FLOORBEAM. REPAIRED FLOORBEAM AS PER AIA SKETCH AIA/E/2492 EA 97-013. REMOVED AND REPLACED SPLICE PLATE AS PER SRM 53-2-0. CORROSION TASK CARD NUMBER 2000-0551. NON-ROUTINE TASK CARD NUMBER 93339.