What was found
DURING C-2 CHECK INSPECTION, FOUND FS260 LEFT NLG TUNNEL HAS STIFFNER CORNER CLIP (TOP OF NOSE WHEEL WELL PRESSURE BULKHEAD 34 INCHES FROM LEFT HAND SIDE) IS CRACKED MARKED S-15. REMOVED AND REPLACED CLIP (7075-T6) IAW B747 SRM CHAPTER 51-10-1 AND 51-30-02 AS REQUIRED. C-CHECK WORK CARD NUMBER 7TK9031. NON-ROUTINE TASK CARD NUMBER 101698.