What was found
DURING C-2 CHECK INSPECTION, FOUND FS 260 RIGHT NLG TUNNEL HAS STIFFENER CORNER CLIP (TOP OF NOSE WHEELWELL PRESSURE BULKHEAD 10 INCHES FROM RIGHT SIDE) IS CRACKED MARKED S-14. REMOVED AND REPLACED CLIP (7075-T6) IAW B747 SRM CHAPTER 51-30-02 AS REQUIRED AND 51-10-1. C-CHECK WORK CARD NUMBER 7TK0115. NON-ROUTINE TASK CARD NUMBER 101699.