What was found
DURING CPCP CHECK INSPECTION, FOUND LEVEL 2 CORROSION UNDER DECK STA 328 TO STA 344 ABOVE STRINGER 19L INNER SKIN DOUBLER SEPARATING FROM SKIN AND CORROSION IN DOUBLER HOLES MARKED K-26. INSTALLED DOUBLER REPAIR IAW AIA/E/2574 SKETCH DTD 6/06/97 AND IAW EA 97-160.A DTD 06/09/97. CORROSION TASK CARD NUMBER C53-111-01 PART 1 OF 3. NON-ROUTINE TASK CARD NUMBER 106971.