What was found
DURING ROUTINE CPCP CHECK INSPECTION, FOUND 2 CRACKS 1.5 APART FS 740 NR 2 FUEL TANK CENTER SECTION LEFT SIDE FOWARD BULKHEAD 5-6.5 FROM TOP LEFT 3.5-6 DOWN. INSTALLED DOUBLER REPAIR IAW EA B2-57-007 DTD 12 AUG 97 AND IAW SKETCH NR AIA/E/2607 REV B DTD 11 AUG 97. CORROSION TASK CARD NUMBER C57-174-01. NON-ROUTINE TASK CARD NUMBER 000394.