What was found
DURING ROUTINE B CHECK INSPECTION, FOUND EXFOLIATION CORROSION ON NR 27RT STRINGER END FITTING AT FS70. REMOVED AND REPLACED STRINGER END FITTING IAW DC8 SRM 53-1-0. NON-ROUTINE TASK CARD NUMBER 001321.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE B CHECK INSPECTION, FOUND EXFOLIATION CORROSION ON NR 27RT STRINGER END FITTING AT FS70. REMOVED AND REPLACED STRINGER END FITTING IAW DC8 SRM 53-1-0. NON-ROUTINE TASK CARD NUMBER 001321.