What was found
DURING CPCP CHECK INSPECTION, FOUND FITTING CORRODED STATION 360, RIGHT BUTTLINE 60. REMOVED CORRODED FITTING IAW B727 SRM 51-30-2. CORROSION FOUND TO BE OUT OF LIMITS IAW B727 SRM 53-10-1. REPLACED FITTING IAW B727 SRM 51-10-1 AND 51-30-2. CORROSION TASK CARD NUMBER C53-224-03 PART 1 OF 2. NON-ROUTINE TASK CARD NUMBER 002049.