What was found
DURING ROUTINE CPCP INSPECTION FOUND LEVEL 2 CORROSION: CORROSION ON MAIN CARGO FLOOR SUPPORT LAST ONE ON LT SIDE JUST FWD OF AFT PRESS BULKHEAD JUST ABOVE APU AIR DUCT. REMOVED CORROSION IAW L1011 SRM 51-21-01. FOUND TO BE OUT OF LIMITS IAW L1011 SRM 53-21-00 FIG 801. REPAIRED FLOOR SUPPORT PER L1011 SRM 51-50-04. INSTALLED PER L1011 SRM 51-40-01. CORROSION TASK CARD NUMBER C53-160-04-00. NON-ROUTINE TASK CARD NUMBER 14045.