What was found
DURING CPCP INSPECTION FOUND LEVEL 2 CORROSION, INTERGRAN CORROSION ON FLOOR SUPPORT (ATTACHED TO T-ANGLE) AT BS 1920 RBL 39. CORROSION FOUND TO BE OUT OF LIMITS IAW B747 SRM 53-10-1. CUT OUT CORRODED FLOOR SUPPORT SECTION IAW B747 SRM 51-40-3. INSTALLED FLOOR SUPPORT AS PER B747 SRM 53-10-23. CORROSION TASK CARD NUMBER C53-110-01 PART 3 OF 5. NON-ROUTINE TASK CARD NUMBER 14781.