What was found
DURING ROUTINE CPCP INSPECTION FOUND LEVEL 2 CORROSION, STRINGER 32 AT STA 1792 CRACKED. INSTALLED STRINGER REPAIR IAW L1011 SRM 53-13-00 PG 806. CORROSION TASK CARD NUMBER C53-120-04-03. NON-ROUTINE TASK CARD NUMBER 15868.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE CPCP INSPECTION FOUND LEVEL 2 CORROSION, STRINGER 32 AT STA 1792 CRACKED. INSTALLED STRINGER REPAIR IAW L1011 SRM 53-13-00 PG 806. CORROSION TASK CARD NUMBER C53-120-04-03. NON-ROUTINE TASK CARD NUMBER 15868.