What was found
DURING ROUTINE C-CHECK INSPECTION, FOUND 2 DENTS ON FUSE SKIN STA 130 TO 135 AT LONG 28 LT. SKIN DAMAGED LEFT SIDE STA 131 TO STA 158 JUST ABOVE LONG 28 LT HOLE 2.5 X 1.0 WITH GOUGE 27 EXTENDING AFT. REPAIRED TWO DENTS IAW COTNEY ENGINEERING DWG D99-R03 REV B AT STA 130 TO 135 AT LONG 28 LT AND REPAIRED SKIN DAMAGE LT SIDE STA 131 TO STA 158 ABOVE LONG 28 LT IAW COTNEY ENG DWG D99-R03 REV B. NON ROUTINE NR 04460 AND 04428 TASK NR N0007.