What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED INTO LT FRAME AT FS 1060 AT UPPER CUSP AREA. FABRICATED ANGLE AND SHIM IAW D93-R07 LT SIDE FRAME FS 1060 LT SIDE. INSTALLED ANGLE AND SHIM, FABRICATED FOR LT SIDE FRAME STA 1060 IAW COTNEY DWG D93-R07. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04826 TASK NR Y1278.