What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED INTO RT FRAME AT FS 1000, 5.5 ABOVE UPPER CUSP AREA. FABRICATED REPAIR IAW COTNEY D93-R46 FROM 7075.0 HEAT TREATED 7075-T6 .071. TREATED AND PRIMED REPAIR. INSTALLED SAME INSTALLED INTERCOSTAL SHIM WITH CLIPS AT STA 1000, R5.5 ABOVE UPPER CUSP IAW COTNEY D93-R46, DC8 SRM 51-1-1, 51-1-21 AND 51-1-20D. CORROSION TASK CARD NUMBER 573R-0551. NON-ROUTINE NR 04881 TASK NR Y1302.