What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED INTO RT FRAME AT FS 1560, 5, 8 AND 13 ABOVE UPPER CUSP AREA. RT FRAME REPAIRED AT FS 1560, 5, 8 AND 13 ABOVE UPPER CUSP AREA IAW COTNEY DWG NR D93-R62, DC8 SRM 51-1-20D, 51-9-0, 51-1-21 PG 9. CORROSION TASK CARD NUMBER 573R-0551. NON-ROUTINE NR 04893 TASK NR Y1314.