What was found
DURING ROUTINE CPCP INSPECTION, FOUND SEVERAL HOLES DRILLED ON LT FRAME AT FS 560, 5 ABOVE UPPER CUSP AREA AND ON RADIUS OF LT FRAME, 20 ABOVE UPPER CUSP AREA. FORMED AND HEAT TREATED PARTS ANGLE -1 IAW DC8 SRM 51-1-1 AND DWG D93-R04. FABRICATED SHIMS AND STRAP INSTALLED PLUG RIVETS IAW COTNEY DWG D93-R04. TREATED AND PRIMED PARTS FOR REPAIR IAW DC8 SRM 51-1-8. INSTALLED REPAIR IAW DWG D93-R04 AND DC8 SRM 51-1-21. CORROSION TASK CARD NUMBER 573L-0551. NON-ROUTINE NR 04898 TASK NR Y1387.